When it comes to fire safety, an important question to ask yourself is: Do I have enough fire extinguishers to protect my property? Whether you’re a property owner, a small business owner, or managing a large commercial property, understanding the right number of fire extinguishers is important to ensure the safety of both people and assets.
In this fire safety guide, we’ll explain the fire extinguisher requirements and amounts for different types of premises and how First Ford can help you stay compliant and protected.
Fire Extinguisher Basics: What Does the Law Require?
So, how many fire extinguishers should a business have? According to UK fire extinguisher regulations, all buildings must be equipped with the proper number and type of fire extinguishers. As a general rule, every premises requires at least two Class A fire extinguishers on each floor, which are specifically designed to handle ordinary combustibles like paper, wood, and textiles.
These extinguishers include water, foam, and dry powder – each variation being able to put out different fire types. It’s important to consider the potential fire risks and select an appropriate type. These Class A extinguishers are a critical first line of defence in most fire emergencies.
How to Calculate the Number of Fire Extinguishers You Need
To determine the exact number of extinguishers required, you need to take into account several key factors, including the size of your premises, the type of equipment in the building, and specific fire risks that are unique to your environment. Fire legislation can initially seem complicated, so we have broken down the basics below to simplify the process. For a more detailed understanding of the legislation, you can read ‘The Regulatory Reform (Fire Safety) Order 2005,’ also known as the RRO.
- Class A Fire Extinguishers: Minimum Two Per Floor
The minimum requirement is to have two Class A fire extinguishers on every floor of your building. These can be 3-litre, 6-litre, or 9-litre models depending on your preference or the specific needs of your building. Class A fire extinguishers are those which put out carbonaceous fires (wood or paper).
- Extinguisher Coverage Based on Floor Space
You also need to ensure that you have one water-based extinguisher, such as water, water additive, or foam extinguisher, for every 200 square metres (or 2,000 square feet) of floor space. This ensures proper coverage across large open areas, reducing the chances of a fire getting out of control before the extinguisher can be accessed.
- Fire Extinguishers for Electrical Equipment
If the premises contain electrical equipment, such as computers, servers, or any electrical appliances, it’s essential to have at least one 2kg CO2 fire extinguisher. These extinguishers are specifically designed to handle fires involving electrical devices without causing further damage to the equipment.
- Special Considerations for Small Premises
In some cases, especially for very small buildings or floors with an area of less than 100 square metres, the number of required extinguishers may be reduced. If adding two extinguishers would make it difficult to evacuate in an emergency, one extinguisher may suffice. It’s important to have an expert fire risk assessment to evaluate your specific situation. An example of a small premises would be a corner shop.
Speciality Fire Extinguishers: Do You Need More?
Depending on your building’s use and the specific risks involved, additional types of fire extinguishers may be required:
- Dry Powder Extinguishers: Ideal for environments where gas risks are present, such as boiler rooms. These are designed for class B, C, and electrical fires.
- Wet Chemical Extinguishers: Necessary for commercial kitchens or buildings with deep-fat fryers, as they are designed to handle cooking oil fires. These are known as Class F fires and have a yellow label.
Can You Reduce the Number of Fire Extinguishers?
In some instances, you may be able to reduce the number of extinguishers in your building. If your premises are equipped with an automatic fire suppression system, such as sprinklers, the need for portable fire extinguishers can be decreased, but it’s still vital to ensure enough coverage for all potential fire hazards.
Using higher-rated fire extinguishers can also potentially reduce the total number of extinguishers needed. One 13A-rated extinguisher can cover around 200 square metres of floor area, so you can cover more space with fewer units.
The Importance of Regular Fire Extinguisher Inspections
Having the correct number of fire extinguishers is just the first step – ensuring they are functional and ready for use is equally important. At least once a month, a responsible person within your organisation should perform a visual inspection of all extinguishers. This should include:
- Ensuring the extinguisher is in its designated place
- Confirming it is unobstructed and visible
- Checking for damage or missing parts
- Ensuring the pressure gauge is within the correct range
- Verifying that tamper seals are intact
Regular maintenance and inspections are key to staying compliant and protecting your premises from potential fire hazards.
How First Ford Ltd. Can Help
As one of the leading fire and security providers in Essex, First Ford specialises in helping businesses and homeowners meet their fire safety requirements. Whether you need a detailed fire risk assessment, the installation of fire alarms and security systems, or assistance in determining the right number of fire extinguishers for your property, we’re here to help.
With our team of experienced fire safety professionals, we provide tailored fire protection solutions that meet both legal requirements and the specific safety needs of your building. We ensure that all systems are fully accredited and insurance-approved, offering you complete peace of mind.
Take Action Today! Don’t wait until it’s too late—ensure your premises are properly protected from fire hazards. Contact First Ford for expert advice on fire extinguisher installation, maintenance, and complete fire safety solutions in Essex.